Dear Bernd,

Thank you so much for your comment. I don't know why i didn't use this 
optim.opts in the first installation. I reinstall DUMUX this time using the 
optim.opts and I don't have the warnings (great).
Now I believe that I have a correct error message.
If i understood correctly my problem is coming from 
injectionspatailparameters.hh where the lphaseIdx is defined 
(test_2pni-error-1).

I tried to change it wPhaseIdx = FluidSystem::wPhaseIdx as i think lPhaseIdx = 
FluidSystem::lPhaseIdx is only valid when we use fluidsystem for example h2on2.

But, I obtained another error about : no matching function for call to 
‘Dumux::TwoPImmiscibleFluidSystem<Dumux::Properties::TTag::InjectionProblem2PNI>::init(double,
 double, int, double, double, int).

Itriedto solve this problem by adding :
SET_TYPE_PROP(InjectionProblem2PNI, FluidSystem, 
Dumux::TwoPImmiscibleFluidSystem<TypeTag>);

but it didn't work.

can you help me please with this problem.

bests,
Ali



________________________________
De : [email protected] 
[[email protected]] de la part de Bernd Flemisch 
[[email protected]
Date d'envoi : lundi 20 août 2012 17:54
À : DuMuX User Forum
Objet : Re: [DuMuX] 2pni problem

Hey Ali,

this is not the full output of the build command, there is no error message in 
there. Most likely, you have a limit in the number of lines stored in your 
terminal window which you can enlarge. You also should consider to use the 
compiler options from the files debug.opts or optim.opts in the dumux directory 
(which you should pass to dunecontrol) such that you don't get the comparison 
warnings.

I also suggest to change the two lines declaring the phase types to
    typedef Dumux::LiquidPhase<Scalar, Dumux::Brine<Scalar, Dumux::H2O<Scalar> 
> > type;
    typedef Dumux::GasPhase<Scalar, Dumux::SimpleCO2<Scalar> > type;

Kind regards
Bernd

On 08/20/2012 05:37 PM, [email protected]<mailto:[email protected]> 
wrote:
Dear DUMUX,

I want to use DUMUX to simulate for Non-isothermal two-phase flow.

I started first working on isothermal two-phase flow and I successfully 
modified tutorial_coupled (in DUMUX /tutorial).

Now, I am working on test/boxmodels/ 2pni and I tried simply using brine and 
simpleco2 as fluids.
In this case, I believe I can use this test without using a fluidsystem (like 
h2on2 used as an example in the original code).
Therefore, I made this simple modification in injectionproblem2pni.hh:

#if 1

// Set the wetting phase

SET_PROP(InjectionProblem2PNI, WettingPhase)
{
private:
    typedef typename GET_PROP_TYPE(TypeTag, Scalar) Scalar;
public:
    typedef Dumux::LiquidPhase<Scalar, Dumux::Brine<Scalar,H2O<Scalar>>> type;
};

// Set the non-wetting phase
SET_PROP(InjectionProblem2PNI, NonwettingPhase)
{
private:
    typedef typename GET_PROP_TYPE(TypeTag, Scalar) Scalar;
public:
    typedef Dumux::GasPhase<Scalar, Dumux::SimpleCO2<Scalar>> type;
};
#else
SET_TYPE_PROP(InjectionProblem2PNI, FluidSystem, FluidSystems::H2OAir<typename 
GET_PROP_TYPE(TypeTag, Scalar)>);
#endif

However it didn’t work and I received an error.
I hope that you can help me with this problem and let me know please if I have 
to make further modification in this test to use brine and co2 instead of 
h2on2fluidsystem. I made some changes (ex. I thought it can come from how the 
indices are defined but I don’t still find know how I can modify them)

Thanks a lot for your help and I look forward to hearing from you soon.
Please let me know if you need more information.

**I send you the injectionproblem2pni.hh where I made my modifications and also 
the error that I received in terminal for your perusal.
In .hh file , I commented my modifications by “my modification”.

Bests
Ali



_______________________________________________
Dumux mailing list
[email protected]<mailto:[email protected]>
https://listserv.uni-stuttgart.de/mailman/listinfo/dumux



--
_____________________________________________________________________

Bernd Flemisch                               phone: +49 711 685 69162
IWS, Universität Stuttgart                   fax:   +49 711 685 60430
Pfaffenwaldring 61                  email: 
[email protected]<mailto:[email protected]>
D-70569 Stuttgart                  url: 
www.hydrosys.uni-stuttgart.de<http://www.hydrosys.uni-stuttgart.de>
_____________________________________________________________________

Attachment: test_2pni_error-1
Description: test_2pni_error-1

Attachment: test_2pni_error-2
Description: test_2pni_error-2

_______________________________________________
Dumux mailing list
[email protected]
https://listserv.uni-stuttgart.de/mailman/listinfo/dumux

Reply via email to