Hi Christoph,

I'm afraid I put it wrong and you did not understand me. I need a free
boundary for the liquid phase. Zero flow means that the fluid does not
leave the area, but I need it to flow out freely. I would use Dirichlet
boundary condition if I could if I could put the border cell pressure as
boundary pressure.  How can I do this?


I work together Kirill Gerke.


Elena

2014-11-24 18:22 GMT+03:00 Christoph GrĂ¼ninger <
[email protected]>:

> Hi Elena,
> you need a Neumann boundary condition with zero flux. Or did I miss your
> question?
>
> Just out of curiosity: What's your affiliation?
>
> Bye,
> Christoph
>
> --
> GDB does hate your application, expresses its contempt through the
> design of its command-line interface.   -- Tom Tromey, FOSDEM 2014
>
>
> _______________________________________________
> Dumux mailing list
> [email protected]
> https://listserv.uni-stuttgart.de/mailman/listinfo/dumux
>
>
_______________________________________________
Dumux mailing list
[email protected]
https://listserv.uni-stuttgart.de/mailman/listinfo/dumux

Reply via email to