Hi, I don‘t think you need 3 models for the dumux multidomain in your case. You can just use the default setup with a different grid. As you just have Stokes and Darcy just make a grid that has some hole/channel spared out (or whatever setup you want). For that you can use e.g. the subgridmanager with dune-subgrid.
A grid doesn‘t need to be connected everywhere, it can also consist of several disconnected patches. You would just need three domains if you have for example Stokes-Darcy1p-Darcy2p or something. Good luck Timo > Am 25.07.2020 um 09:27 schrieb Dennis Gläser > <[email protected]>: > > Hi Mr K, > > from your email I understand that you created a second coupling manager? So > you have something like > > CouplingManager<DarcyTypeTag, StokesTypeTag1> couplingManager1; > > CouplingManager<DarcyTypeTag, StokesTypeTag2> couplingManager2; > > ? > > MultiDomain currently requires a single coupling manager that knows about all > domains, with each domain having a unique domain id. In general, this can be > implemented by inheriting from two specializations of a two-domain coupling > manager. By specializations I mean specialized for different pairs of domain > ids. An example for this is the FacetCouplingThreeDomainManager in > > https://git.iws.uni-stuttgart.de/dumux-repositories/dumux/-/blob/master/dumux/multidomain/facet/couplingmanager.hh > > Besides only inheriting, you need to do some overload resolution efforts in > the dderived three domain coupling manager. In the above file, you can find > examples for all of this. > > For the StokesDarcy two-domain coupling manager, I guess the missing piece is > that the subdomain ids cannot be defined via template parameters but are > hardcoded to 0,1,2. You could try this locally by simply moving them into the > template arguments and use those wherever the 0,1 or 2 are hardcoded. > > Cheers, > > Dennis > > > >> On 24.07.20 18:30, Mr K wrote: >> Hello, >> I want to model porous medium with upper and lower free flow domain. >> I use 2 domain darcy & stokes exercise for doing this. >> I copy stokes problem and rename to stokes2 & change main.cc file >> In main.cc, I struct new coupling manager with stokes2 TTag. >> after making file only first of the stokes type tag recognized. and raise >> error for another type tag. >> how can I correct this problem? >> Is there any example for 3 domain stokes - darcy - stokes ? >> >> >> _______________________________________________ >> DuMux mailing list >> [email protected] >> https://listserv.uni-stuttgart.de/mailman/listinfo/dumux > _______________________________________________ > DuMux mailing list > [email protected] > https://listserv.uni-stuttgart.de/mailman/listinfo/dumux
_______________________________________________ DuMux mailing list [email protected] https://listserv.uni-stuttgart.de/mailman/listinfo/dumux