** Changed in: indicator-power (Ubuntu) Importance: Undecided => Medium
-- You received this bug notification because you are a member of DX Packages, which is subscribed to indicator-power in Ubuntu. https://bugs.launchpad.net/bugs/1430542 Title: Indicator doesn't use weighted average with different-sized batteries Status in indicator-power package in Ubuntu: Triaged Bug description: The indicator implements the spec: https://wiki.ubuntu.com/Power#Handling_multiple_batteries which stated: "Their percentages should be averaged." Apparently this was taken to mean the simple arithmetic mean, and not the weighted average (by the capacity of each battery). http://bazaar.launchpad.net/~indicator-applet-developers/indicator- power/trunk.15.04/view/head:/src/service.c#L1316 shows: const double percent = sum_percent / n_batteries; This means that if one battery is twice as large as another, then after that battery is discharged, 50% would be reported. I'd expect 33%. The code needs to be fixed to reflect the more precise use of the word "average". <https://wiki.ubuntu.com/Power#multiple-batteries>: "Their percentages should be averaged, weighted by the capacity of each." To manage notifications about this bug go to: https://bugs.launchpad.net/ubuntu/+source/indicator-power/+bug/1430542/+subscriptions -- Mailing list: https://launchpad.net/~dx-packages Post to : [email protected] Unsubscribe : https://launchpad.net/~dx-packages More help : https://help.launchpad.net/ListHelp