Default address for the IC-706mkIIg is 58h.

Make sure DX4Win "baud" and Icom menu 35 CI-V Baud are the same.
Default value for Menu 35 is "auto" but DX4Win generally requires
a fixed value - so set menu 35 to the same value as you select for
"baud" (I prefer 9600 or 19200).

I have no information on the eBay cable - there are so any versions
of questionable quality and no support - one would do better buying
an interface from a reputable vendor not the cheapest thing on eBay.

73,

   ... Joe, W4TV


On 11/19/2013 2:12 PM, Jim Reisert AD1C wrote:
From: Jose Silva <[email protected]>
Date: Tue, Nov 19, 2013 at 12:06 PM
Subject: CI-V Help DX4WIN
To: [email protected]

Hello

I can not connect my icom 706mk2 with dx4win, called the CI-V cable. by Ebay

Address 50
Baud 4800
  poll rate 5000
  tries 6
DTR RTS with v
port is ok

Please help me
CU3AN
______________________________________________________________
DX4WIN mailing list
Home: http://mailman.qth.net/mailman/listinfo/dx4win
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

______________________________________________________________
DX4WIN mailing list
Home: http://mailman.qth.net/mailman/listinfo/dx4win
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to