Default address for the IC-706mkIIg is 58h.
Make sure DX4Win "baud" and Icom menu 35 CI-V Baud are the same. Default value for Menu 35 is "auto" but DX4Win generally requires a fixed value - so set menu 35 to the same value as you select for "baud" (I prefer 9600 or 19200). I have no information on the eBay cable - there are so any versions of questionable quality and no support - one would do better buying an interface from a reputable vendor not the cheapest thing on eBay. 73, ... Joe, W4TV On 11/19/2013 2:12 PM, Jim Reisert AD1C wrote:
From: Jose Silva <[email protected]> Date: Tue, Nov 19, 2013 at 12:06 PM Subject: CI-V Help DX4WIN To: [email protected] Hello I can not connect my icom 706mk2 with dx4win, called the CI-V cable. by Ebay Address 50 Baud 4800 poll rate 5000 tries 6 DTR RTS with v port is ok Please help me CU3AN ______________________________________________________________ DX4WIN mailing list Home: http://mailman.qth.net/mailman/listinfo/dx4win Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html
______________________________________________________________ DX4WIN mailing list Home: http://mailman.qth.net/mailman/listinfo/dx4win Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html