Hello,
I have a problem with usage of netconsole and BQL.
If the netconsole is configured to interface without link and any event (with 
netconsole message) happens, the computer starts to print "Reset adapter" 
message cca every 2 seconds.
It's because driver watchdog task times out and resets the adapter and produces 
new message for netconsole.
Without the BQL, the message is put to tx queue and almost immediatelly cleared 
in e1000_reinit_locked.
But with BQL enabled driver, the messages are queued in some upper layer and 
are processed one by one with 2 seconds timeout.
Is there any workaround or patch to fix such behavior (to clear higher level 
queue in reinit?) ?
Thanks in advance.
Petr Cervenka

------------------------------------------------------------------------------