Not everything in the hardware is enabled in the software. We do not appear to 
be using the register you mention.

I have been told by those more familiar with PTP that the Time Sync registers 
are in chapter 8.16 and are only accessible through the PF.

Todd Fujinaka
Software Application Engineer
Ethernet Products Group
Intel Corporation
todd.fujin...@intel.com

-----Original Message-----
From: b.von_h...@wzl.rwth-aachen.de <b.von_h...@wzl.rwth-aachen.de> 
Sent: Thursday, May 5, 2022 5:41 AM
To: e1000-devel@lists.sourceforge.net
Subject: [E1000-devel] [igbvf] Accessing PTP clock from a Virtual Function

Hello,

I'd like to access the PTP timer of an i350T2V2 from a VF. The Datasheet (Rev. 
2.6) states in section 7.8.2.12.2 that "VMs have access to the real time clock 
register". But the only timer-related register which is mapped to a VF I could 
find is the free-running timer (VTFRTIMER at 0x1048). So I'm kind of confused.

P.S. yes I know that there is ptp_kvm module, but it uses hypercalls which I'd 
like to avoid.

Thanks a lot,

Bjarne