mmmh looks like a jumped to conclusions a bit faster. the exact error (when building tests for aaed2000/default) is:
/opt/arm-ecos-elf/lib/gcc/arm-ecos-elf/4.0.2/../../../../arm-ecos-elf/lib/libsupc++.a(vterminate.o): In function `__gnu_cxx::__verbose_terminate_handler()': make: Leaving directory `/home/loki/ecos/ecos-2.0/ecos_build' ../../../../gcc-4.0.2/libstdc++-v3/libsupc++/vterminate.cc:84: undefined reference to `_impure_ptr' so the problem is not in __cxa_pure_virutal() but in __verbose_terminate_handler(). maybe the fix as for __cxa_pure_pirtual() could be done. Any idea? TIA Philippe On Tue, 17 Jan 2006 17:27:20 +0000, [EMAIL PROTECTED] said: > This issue has come up right before the 2.0 release. Id was then solved > by modifying something in the link scripts. The archive of this list > probably can shed some light on your problem. I have been discussing > about this back then with, IIRC, Gary Thomas and Bart Veer. > Bob > > -- http://www.fastmail.fm - A no graphics, no pop-ups email service -- Before posting, please read the FAQ: http://ecos.sourceware.org/fom/ecos and search the list archive: http://ecos.sourceware.org/ml/ecos-discuss