> > Are you sure about this? A quick look at a Strata datasheet (28F640K3) > shows the following:
You are right. My documentation was not that clear. As a word of warning for the searchers, the Numonyx StrataFlash Embedded Memory (P30) downloadable from http://www.numonyx.com/en-US/MemoryProducts/NOR/Pages/P30P33Documents.aspx has this information on Figure 36: Buffer Program Flowchart: Data = N-1 = Word Count N = 0 corresponds to count = 1 Thanks for pointing it out. Edgar > > "Next, a word count (actual word count - 1) is written to the device > at the buffer address. This tells the device how many data words > will be written to the write buffer, up to the maximum size of the > write buffer. The valid range of values for word count is 0x00 to > 0x1F." > > So the (count - 1) in the current code looks right to me. > > Bart > > -- > Bart Veer eCos Configuration Architect > eCosCentric Limited The eCos experts http://www.ecoscentric.com/ > Barnwell House, Barnwell Drive, Cambridge, UK. Tel: +44 1223 245571 > Registered in England and Wales: Reg No 4422071. > -- Edgar Grimberg System Developer Zylin AS ZY1000 JTAG Debugger http://www.zylin.com/zy1000.html Phone: (+47) 51 63 25 00