Thanks Jaben.

I expected this answer. :) Definitely I can't do that as of now.

But do you think this would cause mismatch between the handle index that i
get in my application? The handle index I'm getting is differing, even if
the handle value is same.

And, could you suggest any other ways to fix this, other than embedding my
app into the shell?

Or do you suggest my temporary workaround , in which I'm embedding my own
sermode functionality inside my application ? The functionality​ is working
and I'm able to use com port. But it's annoying to have different
information in app than a shell command! :(

Thanks again.
Regards,
Keshava

On Tue, Jun 6, 2017, 9:45 PM Carsey, Jaben <[email protected]> wrote:

> In general, you should really try to avoid it.  it means you have to build
> and distribute a complete shell instead of a single application.  There are
> some shell commands that simply cannot function without information not
> available via the shell protocol.  If you find you need information, then
> maybe we should consider that missing information to be added to the shell
> protocol.
>
> -Jaben
>
> > -----Original Message-----
> > From: edk2-devel [mailto:[email protected]] On Behalf Of
> > GN Keshava
> > Sent: Tuesday, June 06, 2017 9:12 AM
> > To: Carsey, Jaben <[email protected]>; [email protected]
> > Subject: Re: [edk2] Issue in ConvertHandleIndexToHandle and
> > ConvertHandleToHandleIndex
> > Importance: High
> >
> > Hi Jaben,
> >
> > Thanks for the reply.
> >
> >
> > I understand that the sermode command is in shell, and it's sharing
> > information through libraries.
> >
> >
> > Can you tell me more about the library requirement of module to be linked
> > into shell? How i can do this?
> >
> >
> > Thanks again.
> >
> > Regards,
> >
> > Keshava
> >
> > On Tue, Jun 6, 2017, 9:15 PM Carsey, Jaben <[email protected]>
> > wrote:
> >
> > > That library may require the module to be linked into the shell.
> Remember
> > > that the sermode command is actually in the same binary as the shell
> and
> > > the shell and the command are sharing information through libraries.
> > >
> > > > -----Original Message-----
> > > > From: edk2-devel [mailto:[email protected]] On Behalf
> Of
> > > > GN Keshava
> > > > Sent: Tuesday, June 06, 2017 3:20 AM
> > > > To: [email protected]
> > > > Subject: [edk2] Issue in ConvertHandleIndexToHandle and
> > > > ConvertHandleToHandleIndex
> > > > Importance: High
> > > >
> > > > Hi,
> > > >
> > > > Thanks all for your kind help.
> > > >
> > > > I'm doing few operations using serial port. So, I've done a small
> serial
> > > > driver by referring FTDI code, and I'm accessing this using serialIO
> from
> > > > my application. and it was working fine with older EFI shell.
> > > >
> > > > Now I'm using the latest UEFI shell.
> > > > Now It's working fine for first time. Then if i do any removal and
> > > connect
> > > > of serial port, there is a mismatch in "Handle index" value between
> the
> > > one
> > > > i get in my application, and the one i get in "sermode" command.
> > > >
> > > > I'm using the same code as sermode code, but still, for the same
> Handle
> > > > value, the handleIndex value is deferring.
> > > >
> > > > Whether ConvertHandleIndexToHandle and
> > ConvertHandleToHandleIndex
> > > > functions
> > > > are giving issue? What could be the reason?
> > > >
> > > > Thanks again.
> > > > Regards,
> > > > Keshava
> > > > _______________________________________________
> > > > edk2-devel mailing list
> > > > [email protected]
> > > > https://lists.01.org/mailman/listinfo/edk2-devel
> > >
> > _______________________________________________
> > edk2-devel mailing list
> > [email protected]
> > https://lists.01.org/mailman/listinfo/edk2-devel
>
_______________________________________________
edk2-devel mailing list
[email protected]
https://lists.01.org/mailman/listinfo/edk2-devel

Reply via email to