Le vendredi 29 juin 2007 à 15:57 +0200, Alessio Sangalli a écrit : > Hi, I've been trying to call in local network (same switch, no routing > no NAT, no SIP registration, direct IP call) a linksys-sipura SPA-3102 > with a regular analog phone attached. > > I only had success using the codec "PCMA" or "PCMU", any other codec > would let the telephone ring but, when I picked up the receiver, I > continued to get the calling tone at the ekiga side, altough there was > "connected with IP" on the status label. > > At first I thought that there were "pitch" problems with PCMU but it > seems I had a false alarm due to the eccessive gain used on my headset > microphone. > > The Linksys SPA-3102 shows these choices as "preferred codecs": > G711a > G711u > G726-8 > G726-16 > G726-24 > G726-32 > G726-40 > G729a > G723
A -d 4 debug trace would be useful, but I think the only common codecs are G.711a and G.711u... -- _ Damien Sandras (o- //\ Ekiga Softphone : http://www.ekiga.org/ v_/_ NOVACOM : http://www.novacom.be/ FOSDEM : http://www.fosdem.org/ SIP Phone : sip:[EMAIL PROTECTED] _______________________________________________ ekiga-list mailing list [email protected] http://mail.gnome.org/mailman/listinfo/ekiga-list