Hi Hernán,
thank you for testing.
Julio Sosa schrieb:
Hi! I could try ekiga again:
I have Debian GNU/Linux 5 with ekiga 3.2.5 wich I got from one of these
repositories don't remember wich, I think the second one, I do also have a
Linksys router with 2 VoIP lines, one with sip.megavox.com.ar and the other
with iptel.org. The corresponding ports of the router are forwarded to the
computers ones. My accounts on ekiga softphone are (ekiga, iptel and megavox).
# deb http://corvix.eu testing ekiga
deb http://blaniel.free.fr/debian/lenny-backports/ ./
# deb http://snapshots.ekiga.net/snapshots/debian/ ./
. My girlfried has Windows XP with ekiga 3.2.pre6 wich she got from
http://wwwuser.gwdg.de/~mrickma/ekiga/ekiga-setup-3.2.pre6-release.exe
She has an ekiga account in her ekigasoftphone.
Ok, this is what happen, I put my ekiga and my girlfriend codecs in this order from top to bottom:
MY COD GIRLFRIEND
speex 8k speex 8
speex 16 speex 16
g726-32 ilbc
g726-16 g726-32
g726-24 g726-16
g722 g726-24
pcma g722
pcmu pcma
g726-40 pcmu
gsm g726-40
ms-gsm gsm
celt 32 ms-gsm
celt 48 celt 32
------- celt 48
After that we put jitter from 500 to 150 ms.
Then she told me she was going to connect to test ekiga and I don't know why
when she connected then I got all my accounts disconected.
Hours latter I connected first, and everything ok, but when she connected I got
my ekiga.net account disconected, the others didn't get disconected.
This router buisyness is so difficult. I can not really help there. Did
any of you try to call [email protected]?
Latter again I could call her but according to the codecs prefference the call should be with the speex 8hz codec and I wan't with that. It was with celt! but I couldn't speak nor hear. Then I disallowed celt codec and voila! I got the comunication with the speex codec!
I guess calling each other worked here because you were using the
internal IPs. In your logs the sequence of codecs seems ok. I do not
know why CELT gets a higher priority all of a sudden. But that you could
not hear each other once you agreed on CELT is significant. We had
already a short discussion on compatibility of different CELT versions
on the devel-list, see the final statement of Gregory Maxwell:
http://mail.gnome.org/archives/ekiga-devel-list/2009-July/msg00093.html
. Win32 Ekiga uses CELT 0.51 at the moment as I thought there may be a
bit of compatibility using an older version. But now I see that CELT is
a "no go" at the moment and will take it out of the Win32 build.
Thanks
Michael
Conclusion: 1) ekiga for some strange reason get disconected at the time other
contact get connected (my hipothesis).
2) ekiga does not always follow the codec preferences.
Today I saw how to do the debug of linux:
http://wiki.ekiga.org/index.php/Debugging_Ekiga
So with this email I am sending the debug (compressed with 7zip).
Thank you for making ekiga better!
Hernán.
[....]
_______________________________________________
ekiga-list mailing list
[email protected]
http://mail.gnome.org/mailman/listinfo/ekiga-list