Hi Sergey,

> I just opened Freescale FS from
> http://cache.freescale.com/files/32bit/doc/fact_sheet/MPC8309FS.pdf?fpsp=1
> It shows  Floating Point Unit  - YES
>
> Where the correct answer?

It seems you are correct and the 8309 has a floating point unit.  Maybe
Wolfgang was over-cautious as at some time we believed that all of the
83xx family had an FPU but interestingly it turns out the 8321 and 8323
are an exception to this "rule".

Cheers
  Detlev

-- 
Erst wenn der letzte Programmierer eingesperrt und die letzte Idee
patentiert ist, werdet ihr merken, dass Anwälte nicht programmieren
können.
--
DENX Software Engineering GmbH,      MD: Wolfgang Denk & Detlev Zundel
HRB 165235 Munich,  Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-40 Fax: (+49)-8142-66989-80 Email: [email protected]