I set the VFO to 7.000 MHz. Vertical to 50 mV / division Channel 1 Trigger Auto Horizontal wide open (about 5 cycles on the screen)
Probe to 1x U4 P1 probe loaded circuit, oscillation stopped Probe to 10x U4 P1 4.50 divisions (4.5 * 0.050 * 10 = 2.25, .86 RMS - Spec: 0.8-1.8) U3 P3 2.25 divisions (2.25 * 0.050 * 10 = 1.125, .43 RMS - Spec: 0.3-0.4) U3 P6 4.50 divisions (4.5 * 0.050 * 10 = 2.25, .86 RMS - Spec: 0.6-0.75) hth Dan / WG4S / K2 #2456 <snip> OK, go with step 2-3-4 on page 10 "Signal tracing" </snip> _______________________________________________ Elecraft mailing list Post to: [email protected] http://mailman.qth.net/mailman/listinfo/elecraft You must subscribe to post. Subscriber Info (Addr. Change, Unsub etc): http://mailman.qth.net/subscribers.htm Elecraft page: http://www.elecraft.com