I've noticed something with my K2/100 and wonder whether this is normal
behaviour or not ??

When I switch to a new band and send CW using full power, I don't seem to
get full output power on the first couple of dits (or dahs), according to
the bargraph power meter. After the first couple of dits the meter reads
full scale, and continues to do so whilst I remain on that band.

I also get the same thing when the turn the power back to 10 watts.. I only
get the first 1 or 2 LEDS lit with the first couple of dits, but then full
scale on the rest.

Any ideas..

Cheers

David, VK2NU