Julius,

Off hand, without doing the design, I'd say something on the order of one F-140-43 or two F-114-43. You can't get there with a T-XX-6; not enough umph. Takes F-XX-61 at the least. Why limit it to 160 to 30 meters? The BL-1 covers 160 through 6. See http://www.njqrp.org/balun/index.html

Chas,

W1CG

At 02:25 PM 10/12/2004, J F wrote:
Greetings All,

Ok, I want to build a balun. It should be able to
handle 200 Watts RF (safety factor built into this
number), 80 thru 30 Meters (160M would be nice) and be
efficient. I want to use a Toroid to do this so it
fits inside an enclosure. My question is how small of
a toroid can I use and which variety? I'm thinking
something in the T-100-6 range.

Thanks,
Julius
n2wn


_______________________________________________
Elecraft mailing list
Post to: [email protected]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply via email to