Many thanks, I was confused but now it works fine. 73 de Lutz (DL7AVC) ---------- Forwarded Message ----------
Subject: Re: [Elecraft] KPA100 CAL tPA Date: Sunday 31 October 2004 15:47 From: [EMAIL PROTECTED] To: Lutz Pflughaupt <[EMAIL PROTECTED]> Remember you must press the edit key to move the edit line under the temp and then press the edit key then you can change the temp with the vfo knob then press the menu key two times to return to the normal display. 73 Jim Younce K4ZM -------------- Original message -------------- > Hi Folks, > my problem: > After finishing all adjustments and calibration (also CAL tPA) without any > problems, I wat to recheck the CAL tPA. Now on my display only " tPA 0C" > shown. Is not possible to change temperature by VFO-knob. > Many thanks Lutz (DL7AVC) > _______________________________________________ > Elecraft mailing list > Post to: [email protected] > You must be a subscriber to post to the list. > Subscriber Info (Addr. Change, sub, unsub etc.): > http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/subscribers.htm > Elecraft web page: http://www.elecraft.com -------------------------------------------------------
_______________________________________________ Elecraft mailing list Post to: [email protected] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com