Hello,

just completed my K2 to the Alinment and Test Part II.
Here i have some problems...
With the VCO test I always measure 8v at R30.
The voltmeter reading does not change at all i tune L30 or the VFO.
Thus I have thought T5 am wrongly wound. But no change after rewound it...

The Troubleshooting in the manual was not a big help.
I measured there the following voltages:

Reference Oscillator Output, Pin 1 of U4:   1.1V
VCO Output, Pin3 of U3:   0.4Vpp with an DC offset of  4v
VCO Buffer output, Pin6 of U3:   0.8Vpp with an DC offset of  4v
R30 left side:   always 8V

Can someone help me?

73 Peter - HB9DUT

_______________________________________________
Elecraft mailing list
Post to: [email protected]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply via email to