I modeled the switch and have identified the source of the problem. There is a resonance formed between the junction capacity of D12, D14 and the 100uH inductor RFC3. When you add the 12pF cap or a scope probe, all you do is move it around a little. The easiest way to kill this problem forever is to replace RFC3 with a 1K resistor. That will introduce an additional receive path loss of 0.216 dB which is negligable. Try it and let me know what you see.

Bob