Earl,

You may want to touch up the soldering on T1-5 and T1-4 first. Either T1 has a broken primary wire or a bad solder connection. The 300 ohms resistance reading is proper with an open primary - R22 is in parallel with the T1 primary winding.

73,
Don W3FPR

----- Original Message ----- My KPA100 has no RF out. Low power from the K2 is great. In checking I find RF as far as T1-5 then it stops. The primary winding shows 300 ohms to ground from T1-5. Does this teflon wire have that much resistance?? I guess I just dont understand why the power is not being transferred and would appreciate some help from others.
Thank you, EArl VE3FBK