On page 60 of the K2 manual the PLL Reference Oscillator Range Test
asks for the Ref. High Freq. and Ref. Low Freq. measurements. I have
HI = 12099.67
LO = 12090.50
DIFF 9.17
which is less than the 9.8 to 15 kHz required by the manual.
Everything else looks good. Any ideas? Any help would be
appreciated. Thanks.
-- Scott (NE1RD)
PS What a beautiful kit. I'm loving it!
B. Scott Andersen | "Magic is real, unless declared integer."
[EMAIL PROTECTED] | -- The collected sayings of Wiz Zumwalt
Acton, Massachusetts | Ham: NE1RD, QRP ARCI#11588, FP#-910
_______________________________________________
Elecraft mailing list
Post to: [email protected]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com