Some ask for more info. With the probe in TP2 and CALL on FCTR the reading jumps fast around 4.620 mc Then the voltage on RP6 is stable reading 6,48V
Pressing BAND - The readout is 4,917 mc and stable but the voltage on RP6 has jumped to 8,0V > > I have a K2 rig here for repair and this baby has a instable frequentie > reading on TP2 > After touching a part of the bfo its solid (4,917 mc) > Q24 is working good, but on U11 (bfo) pin 6 and 7 are 1 volt too low. > I a have all ready replace D37 and D38 bun no effect. > > Question. Why are there 2 cristals? (X3 and X4) > The low voltage on pin6 and 7 of U11 is this caused by a defect IC or > something else? > > Peter > PC2A > _______________________________________________ Elecraft mailing list Post to: [email protected] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com