I'm in a very stormy country (Northern Alps) and we have at least once per month a thunderstorm that already cost me one pair of power Xstors (in my TS-130 - $380!!!) so even with $5 each TO220 part, I did not want to loose them, or at least reduce the chance to loose them.
So I instaled on the KAT2 control board an RF Chock (1 mH) and an NE2 neon bulb wired between K18-pin 3/8 and ground just to establish a direct lway to ground for static electricity (via the chock) and in case of a virulent one turn on the NE2 and establish a full short to ground. Up to now I did not constat any loss of performance, either in transmission or reception and not changes in the KAT2 function. So... 73 to all and also a very heavy thank to all on the list, even if I do not use the information, it is a nice place to wander (hi!) F5UL/Robert _______________________________________________ Elecraft mailing list Post to: [email protected] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com