Bill W4ZV wrote: > > 3. Adjustment resolution of the P3's Ref Cal steps. Adjustment steps are > 10 Hz (at the P3's 60 MHz clock). At WWV's 15 MHz (1/4 of 60 MHz), each > adjustment step is 1/4 of 10 Hz = 2.5 Hz, which results in a maximum 1/2 > step uncertainty (1.25 Hz) in adjustment resolution when centering the P3 > display. >
Both Al's previous post which I missed and a PM from Lyle correct the above: "The P3 is dealing with the 8.215 kHz IF frequency regardless of the signal frequency that is displayed on the center of the screen, so the steps are more like ((8.215/60)*10=) 1.4 Hz." 73, Bill -- View this message in context: http://elecraft.365791.n2.nabble.com/P3-a-modest-proposal-for-QSY-tp5410950p5416262.html Sent from the [K3] mailing list archive at Nabble.com. ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html