Hi Don and the list, I am making some progress but still trying to find some more power. I decided to stop tweaking and take some measurements so we can compare good & bad and try to understand what we are expecting to see.
The data is on my blog @ http://www.hoaglun.com/blog/ The XV144 is working fine. The XV222 and XV432 are still having issues. I am going to go back thru the filters again and try to peak my levels. Any other guidance that you might have to offer would be appreciated as I am starting to think about grasping for straws. :-) 73 -- John Hoaglun NG0R - EN25 http://www.hoaglun.com On Sat, 2010-08-21 at 22:38 -0500, John Hoaglun wrote: > Hi Don and the list, > > After replacing R6 on the KAT2 board I went back thru the transverters > to see where I am at after the change. > > XV144 - ~1mW of drive = 12w power (into a Bird 43 slug + dummy load) > Target is 25w > XV222 - ~.42mW of drive (virtually no power out) Target is 10w > XV432 - ~.50mW of drive (virtually no power out) Target is 10w > > I decided to go back to the XV432 since that is what we have been > talking about recently. After peaking the filters again and I am > seeing about 1.9V at TP6. What kind of number should I see? > > I will pick this up again in the morning when I my mind is fresh. > ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html