I've not seen this, but your VFO B area is probably showing power supply 
voltage when a power level is expected.  

Can you save your configuration with the K3 Utility, then perform parameter 
initialization (EE INIT) then restore configuration?  EE INIT is described in 
the K3 Owners manual.

Dick, K6KR

Sent from my iPhone

On Sep 20, 2010, at 1:50 AM, "Jeff Cochrane - VK4BOF" 
<[email protected]> wrote:

> Hi everyone,
> 
> I am attempting to do a TX Gain Calibration and every time that I have 
> attempted it so far, I get the following response from the K3 Utility. 
> 
> --------------------------------------------------------------------------------
> 
> 
> Starting 5 watt calibration
> 
> Calibrating at 1.900 MHz
> 
> Calibration power settled at "13.5 V ;"
> 
> Elapsed time: 12 seconds
> 
> Tx Gain calibration failed because transmit power did not reach the expected 
> value
> 
> 5 watt calibration failed
> 
> 
> --------------------------------------------------------------------------------
> 
> I get the same error if I bypass the 5 watt test and go straight to the 
> 50Watt test.
> I have tried it with the radio running on a battery and with a regulated 
> power supply.
> I am using the latest  version of the K3 utility.
> 
> Any idea's?
> 
> Jeff Cochrane
> VK4BOF
> East Innisfail QLD
> Australia
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:[email protected]
> 
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to