For getting to Q24 leads, yes the SMT diode gets in the way, but I 
have found that most builders have left the leads long enough to bend 
the board assembly up enough to allow access to the Q24 leads.  That may 
or may not be the case with your construction, but I mention it just in 
case.  Unsoldering one lead to swing it out of the way is not a big deal 
either.  My preference is to unsolder the lead from the RF board 
(leaving it attached to the small board) - it is easier to re-install 
the diode that way.

73,
Don W3FPR

On 10/4/2010 10:18 PM, Brian Denley wrote:
>
> I attempted to check Q24 but it's solder joints are placed right under the
> small SMT board that is mounted on the backside of the RF board and
> difficult to reach unless I remove that board.
>
> Brian Denley
> http://home.comcast.net/~b.denley/index.html
>
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to