Hi All. My new K3 is alive and well. One thing has me stymied and that is the Wattmeter calibration procedure. I believe I've followed the manual's prodecure to the letter each time but I'm confused about which menu entry should be adjusted as the number on the VFO A line does not change when TUNE is active. What I have done instead is to press XMIT to kill the carrier after reading the value on the Wattmeter and then setting WMTR HP to the real Wattmeter value and pressing TUNE again to see that the K2's Wattmeter and the external meter now each read 50 Watts. If that is correct, could this be made a bit more clear? This had me running in circles last night!
73, de Nate >> -- "The optimist proclaims that we live in the best of all possible worlds. The pessimist fears this is true." Ham radio, Linux, bikes, and more: http://n0nb.us/index.html ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html