In the process of investigating this further, I tripped over a very nice
diagnostic tool: the Config menu's "SW TEST" entry. This option can be set
to "SCN ADC" to allow monitoring of the 4 potentiometer inputs to the PIC
processor ADCs. This allows one to verify the range and linearity of the
pots very easily.

As expected, the ADC outputs produce a linear count ranging from 002 to 240
for the full travel of the pots (all 4 of them exhibit the same results). 
Those counts correspond to input voltages (from the pots) of 0.039V and
4.71V, respectively, which are essentially what I measured with my
voltmeter.

This method is MUCH easier, however, and eliminates any question as to what
the ADC is actually seeing on its inputs.


-----
73, Stan - KR7C
-- 
View this message in context: 
http://elecraft.365791.n2.nabble.com/K3-Rf-gain-tracking-main-vs-sub-tp5668917p5673239.html
Sent from the Elecraft mailing list archive at Nabble.com.
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to