George, The first thing to check is the setting of CAL tPA. If that does not cure your problems, ask here again.
73, Don W3FPR On 10/31/2010 11:05 PM, George Winship, NC5G wrote: > My shack is in a separate building from the house and is not heated or cooled > unless I am in there. Twice, since the weather has finally cooled here in > Texas, I have had the following problem with my KPA 100. When I turn on the > K2/100, the cooling fan immediately goes to high speed. When keying the rig, > the display shows "Hi Refl" followed by "PA HOT". There is no output. > Turning the power down to below 10 watts to turn the KPA 100 off allows the > K2 to transmit, but the fan stays on. Both times that this has happened the > shack temp was in the forties. After the shack and radios warm up all is > normal again. Visual inspection has not revealed anything. > > Any ideas on where and what to look for? BTW, the K2/100 has been in this > enviroment for several years with no problems. > > ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html