Great, done, thanks.
73
Claude VE2FK
----- Original Message -----
From: Don Wilhelm
To: Claude Du Berger
Cc: [email protected]
Sent: Monday, November 22, 2010 10:15 AM
Subject: Re: [Elecraft] Ref Osc Calibration
Claude,
Turn TECH MD on in the CONFIG menu first and then you will see it.
73,
Don W3FPR
On 11/22/2010 9:57 AM, Claude Du Berger wrote:
> Hello Group
> I want to calibrate my K3, presently about 10Hz off.
> I want to use method 2 in page 50
> I can not find CONFIG:REF CAL in the menu...
>
>