Do you have voltage at the drain of Q24 when in CAL FCTR? You must have voltage in order for the signal to pass through Q24. If so, then trace the BFO signal with your 'scope. Both ends of L33 Then through D37 Then to the gate of Q24. Then the source of Q24.
Let us know where the signal is lost. I will provide additional help when you sign your posts with your name and callsign. This is a reflector of other users, not a support organization, even though some of us do offer support here - anonymity is not really welcomed. 73, Don W3FPR On 12/3/2010 4:02 PM, kruegerbenny wrote: > Yes, its a K2 (sorry) > The internal counter probe works, already tested in the earlier tests > At U11 pin 6, I got a signal with 4.930kHz (2,4V peak to peak) > > Any idea? ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html