Hi all, I am having problems with my K2 after moving it from one room to another. K2/100 into a dummy load On all bands I get a HiCur notice when I try to tune, when the PA is disabled (10 watts or less) the SWR shows 1:1 OK On all bands with the PA enabled (over 10 watts) I get the HiCur notice and the SWR indicates a fluctuating range from 3:1 to 9.9 to one depending on band and power setting. In all instances the power out indication is markedly lower than the setting. At 10 watts set, I show 4 watts, at 90 watts set I show 7 watts. I have misplaced my analog wattmeter during the moving process but my LDG autotuner shows that output is actually near or above my settings. Not a good diagnostic tool I know. I think something has definitely gone awry, any ideas on where to start?
Thanks, Allen, W1SBY ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html