Eugene,

An external reference for the K2 would achieve nothing dynamically.

The K2 stores its frequency information in EEPROM and retrieves that 
info during operation.
The only time an accurate frequency reference would be a benefit to the 
K2 is during the dial calibration steps of adjusting the 4 MHz reference 
oscillator and then running CAL PLL and CAL FIL afterward.

See the K2 Dial Calibration article on my website www.w3fpr.com for more 
information.

Merry Christmas and a Happy New Year to all on the Elecraft reflector.

73,
Don W3FPR

On 12/24/2010 5:12 PM, Eugene Balinski wrote:
> All,
>
>     Any chance of an external reference input for the K2?
>
> 73
> K1NR