Tap the Menu button, turn Select until you see "FixTrack" then
tap the select knob.  That will return the P3 to the tracking
mode.  The new firmware defaults to the "fixed" mode.

The "center" cursor is not active in the Fixed mode.

73,

    ... Joe, W4TV


On 1/22/2011 12:14 PM, Andrew Catanzaro wrote:
> Upgraded to the P3 firmware version 1.00 today.  I lost the center
> frequency marker and the spectrum displayed no longer follows the VFO.
> The cursors for both VFO's display normally.  The markers A&  B work
> normally.  I know I am overlooking something simple, but cannot get this
> figured out.  Please CC me off list as I receive in the digest format.
> Thanks.
>
> Andy W9NJY
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:[email protected]
>
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
>
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to