Update: At lunch I used the signal tracing handout and could not inject a signal into TP#1 and hear any change at all. I verified all the parts and installation direction of all the items in the handout as well as reflowing the solder points with no change. One item of note is that the static hiss does change at all when changing freqs by moving the knob or by changing bands with the BAND +/- buttons.
74, John KD7ZYR -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of John Bonk Sent: Monday, May 23, 2005 9:19 AM To: [email protected] Subject: [Elecraft] Cannot hear internal ref. signal Hello all, I am working on the 2nd of my two K2 kits while my first is waiting for some flux-off and have reached the IF Amplifier Alignment and cannot hear the internal signal. All resistance checks and alignment up to the point has been without issue. I checked and rechecked the board for solder problems last night without any luck. Any suggestions on where I might focus my search? 73, John KD7ZYR _______________________________________________ Elecraft mailing list Post to: [email protected] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com _______________________________________________ Elecraft mailing list Post to: [email protected] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com