Roy,

Be certain you have T-R set to HOLD.  See page 89 of the manual.  The 
T-R setting determines the delay, and the 8R hold or normal settings 
will influence the behavior of the 8R signal (that signal controls the 
K2 "keyout" timing.

At what code speeds - yes at slow speeds, the relays will "chatter" no 
matter what the settings, but at 20+ wpm, the relays should hold in 
between characters.

The K2 uses silent electronic T/R switching, but the XVxxx transverters 
use relays for T/R functions.

73,
Don w3FPR

On 4/2/2011 1:11 AM, Leroy Marion wrote:
>    I just finished a XV50 transverter. Using it with a K2
>
> with the KI02 control.
>
>    It seems to work OK when keyed for SSB. When I use
>
> CW, its relays click and chatter like mad. Do I have
>
> some thing set wrong?
>
>
______________________________________________________________