RC, This may be dumb of me, but did you do these steps?? Set the ATU parameter to CAL using the menu. 1) Pre-set potentiometers R1 and R2 on the bottom of the ATU board to exactly their mid-points. 2) Touch the (+) lead of a digital multimeter (DMM) or analog voltmeter to the small hole near the "REFL" label on the bottom of the KXAT1 board. Connect the (-) lead to one of the KX1's long standoffs. 3) Set the voltmeter for 2 or 3 DC volts full scale.
Just a thought... Dave KK7SS _______________________________________________ Elecraft mailing list Post to: [email protected] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com