Vic, I am going to lobby for an "Amp Inhibit" input in every amplifier that will accept exactly what your external relay driven by DIGOUT1 signal is doing. :-)
IT does not have to place the amp in standby, it just opens the Key In line, and would be easily be done inside the amplifier. When the signal is present, the amp ignores the Key In line. 73, Don W3FPR On 5/31/2011 6:10 PM, Vic K2VCO wrote: > I use the DIGOUT1 line to enable my amp, as someone mentioned. It's reliable > because you > can turn it on or off and not just change its state, as with some other > parameters. > > You would be amazed at how much output you can get from a single 3-500Z (for > a very short > time!) if you hit it with 110 watts of drive. I found out before implementing > DIGOUT1, but > luckily the tube survived. > ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html