Vic,

I am going to lobby for an "Amp Inhibit" input in every amplifier that 
will accept exactly what your external relay driven by DIGOUT1 signal is 
doing. :-)

IT does not have to place the amp in standby, it just opens the Key In 
line, and would be easily be done inside the amplifier.  When the signal 
is present, the amp ignores the Key In line.

73,
Don W3FPR


On 5/31/2011 6:10 PM, Vic K2VCO wrote:
> I use the DIGOUT1 line to enable my amp, as someone mentioned. It's reliable 
> because you
> can turn it on or off and not just change its state, as with some other 
> parameters.
>
> You would be amazed at how much output you can get from a single 3-500Z (for 
> a very short
> time!) if you hit it with 110 watts of drive. I found out before implementing 
> DIGOUT1, but
> luckily the tube survived.
>