I use TX-INHIBIT on my K3 and have a webpage showing how:
http://www.kl7uw.com/TX-INHIBIT.htm

The circuit does include the FT-847 so is more complicated than you 
need.  Instead of the voltage regulator you apply 5v thru a 2.2 to 
10K resistor directly to pin-7 on the K3 ACC jack.  The Station 
Master must ground pin-7 to enable transmitting.  Where you obtain 5v 
is an issue and it seems it should be available on one of the ACC 
pins.  I'm not doing that.

Ed - KL7UW

------------------------------

Message: 41
Date: Thu, 2 Jun 2011 21:49:26 +0300
From: "Natale Borghetti" <[email protected]>
Subject: [Elecraft] K3+ Station Master
To: <[email protected]>
Cc: ik5baf <[email protected]>
Message-ID: <4B97334D58D747B48357D4EB40E3B482@natale>
Content-Type: text/plain;       charset="iso-8859-1"

Hi OM,

I need some help...I have to connect my K3 to Station Master to have 
the TX INIHIBIT, I have understand that have the TX INIHIBIT at pin 7 
of K3 and this has to be connected to the TX INIHIBIT of Station Master.
I read page 19 of K3 Manual that says:
"An external 2.2 to 10 K pull-up resistor (to 5VDC) is required".

Well that is NOT very clear to me.....(perhaps I am to old...Hi), 
could some more clever explain better how to do it or a small 
schematic will be appreciated as example where is the 5VDC ???


I thank you in advance for help and assistance on interpretation..

73 and DX

i5NPH




73, Ed - KL7UW, WD2XSH/45
======================================
BP40IQ   500 KHz - 10-GHz   www.kl7uw.com
EME: 50-1.1kw?, 144-1.4kw, 432-100w, 1296-testing*, 3400-?
DUBUS Magazine USA Rep [email protected]
======================================
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to