John, that's more evidence that it's the forward and reverse power detection 
diodes in the KPA100 that failed since when you remove it the power detection 
function is handled by a separate diode detector in the base K2.

The base K2 doesn't have a full forward/reverse power detection circuit to 
calculate SWR. It uses a simpler diode detector to only measure the output 
power at the antenna connector and reports the power assuming a 50 ohm 
non-reactive load. The detector output tells the K2 when it is producing the 
power requested by the POWER control. 

Ron AC7AC