Mike, It will not be necessary to change the CAL OPF menu settings unless a crystal is changed on the 4 band board. The calibration that is necessary with a change of a capacitor in the VFO is the VFO calibration which is achieved by changing the turns spacing on L1.
73, Don w3FPR On 7/8/2011 4:16 PM, Mike Morrow wrote: > >> Next, recalibration of the four bands will be required, per the KFL1-4 >> four-band filter board manual. > I'll emphasize that this WILL be necessary, not only due to the new > capacitor, but also because you will likely alter the turn spread on > VFO toroid RF-L1 while working so close to it to change RF-C2. > > Mike / KK5F > ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html