>>"the meter reads 7.9 volts If this is the metering internal to the KPA500:
Maybe the transformer taps are wrong or bad? If we had a schematic of the power supply we could find a location to measure the HVDC with an external meter. (This would be like working on the plate supply of an old vacuum tube amp, not like working on a 12V powered QRP rig -- be very careful! ) Maybe it is really 79 volts, but the display has a stuck decimal point? Does that decimal point stay _all_ the time? Even when the display is used for other readings/messages? Mark AD5SS On Fri, Sep 9, 2011 at 11:38 PM, Steve Wender <[email protected]>wrote: > Hi all, > > I just completed assembling a KPA500 and got as far as the power supply > test. > When I do the power supply voltage test, the meter reads 7.9 > volts. Doesn't sound right. > > Any thoughts? > > thanks, > > Steve > > ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html