Don,

DATA A and AFSK A are not the same. For PSK31 with a center frequency of 
1500 Hz, you should be using the DATA A submode.

In AFSK A, which is really intended for Baudot RTTY only, the normal or 
default filter center frequency is controlled by the PITCH setting; with 
the default PITCH setting of 2125-170, the normal center frequency is 
2210 Hz. There is no PITCH setting that corresponds exactly to a center 
frequency of 1500 Hz, although the 1445-170 setting is pretty close 
(1530 Hz). In DATA A, the default center frequency is 1500 Hz.

Also, you will find in AFSK A that your dial frequency reading is 
different from everyone else's; AFSK A uses the lower sideband and the 
dial displays the actual RTTY mark frequency, whereas DATA A uses the 
upper sideband and the dial displays the suppressed carrier frequency.

73,
Rich VE3KI

NA6Z wrote:

> So I've been using TX DATA/AFSK A for PSK31 on 20M for quite a while with no
> problems. With the recent activity on 10M, I thought I'd give PSK31 a try up
> there. For whatever reason my 2700 Hz filter is centered on 1500 Hz (as I 
> would
> expect), but my 500 Hz filter is centered on 2210 Hz. It turns out that's the
> case for all bands except 20M. It's been so long I don't remember what I did 
> to
> change the default. How do I change all those defaults to 1500 Hz without
> having to use the shift knob? In other words, I want the bandpass display on
> the front panel to show centered when the filter is centered on 1500 Hz.

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html