This probably has nothing to do with using RIT. The K3 takes a few seconds to recognize that the amp is on line and then respond by switching to the KPA500 power table.
Give the K3 slightly more time. Either swap the amp-On/RIT ON operations by enabling the amp first, use the amp's automatic ON>OPER mode, set your K3 per band power setting lower, or wait another second or so before sending the first dit. 73 de Bob, K6XX r miles <[email protected]> wrote: > >Since I got the KPA this has happened three times. I get so used to >being almost instant go I may be too fast. >K3 on & I see a DX spot. I hit the on switch on the KPA. I push the K3 >RIT on in case I want to use it. With in 2 or 3 seconds I hit the >operate button on the KPA & send a Dit. KPA red lights. I punch the KPA >to standby & take a breath. I go to operate on the KPA & all is normal. >If I don't punch on RIT this hasn't occured. Am I just too fast & the K3 >is getting too many commands at once. There's no damage just a wake up >call to the operator. All this happens in just 3 or 4 seconds. >Operator error? > >K9IL >______________________________________________________________ >Elecraft mailing list >Home: http://mailman.qth.net/mailman/listinfo/elecraft >Help: http://mailman.qth.net/mmfaq.htm >Post: mailto:[email protected] > >This list hosted by: http://www.qsl.net >Please help support this email list: http://www.qsl.net/donate.html ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html