It sounds like you are getting no RF to the amp. This is normal behavior for an 
amplifier 
which is in transmit mode but is not getting any drive.

On 1/10/2012 7:56 AM, Ian Kahn wrote:
> All,
>
> I recently acquired a used Ameritron AL-811H for use with my K3 (until I
> can save enough to get the KPA500).  I seem to be having issue getting the
> amp to respond to key down on the rig.  I have an RCA cable running from
> KEY OUT on the back of my K3 to the RELAY on the back of the amp.  I have
> DIGOUT1 on the K3 set to ON.  The amp is configured for, and plugged into,
> a 240V AC outlet.  When I go key down, either in CW or SSB, I only get a
> plate current of about 120 mA and don't get any grid current.  I suspect I
> have something misconfigured and the issue is operator error, but I'm at a
> bit of a loss as to where to look at this point.  Can anyone offer any
> guidance?
>
> Thanks and 73,
>
> Ian Kahn, KM4IK
> Roswell, GA
> [email protected]
> K3 #231, P3 #688
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:[email protected]
>
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html

-- 
Vic, K2VCO
Fresno CA
http://www.qsl.net/k2vco/

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to