Don, I suggest you skip that. First of all, the 100 hZ increments are not close enough, and secondly, the exact frequency of the 4 MHz reference may end up slightly different than 4 MHz. Wait until you have fully assembled your K2 and then go to my website www.w3fpr.com and do the K2 Dial Calibration procedure - it will put the 4 MHz reference on the correct frequency and give you correct dial calibration.
73, Don W3FPR On 1/21/2012 6:40 AM, Don Baucom wrote: > I have a chance to pickup a Kenwood DG-5 freq. display for my TS-520SE. It is > also a 40mhz counter in 100hz increments. Could I use it for the 4 mhz > oscillator Calibration on page 63. Is the DG-5 accruate enough for this > purpose. > > Im getting close to this test point ( Im putting the crystals in today and > will wind some toriods) > > ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html