Werner, Is that with the base K2 (no KAT2, no KPA100 and no KAT100)? If so, is the K2 operating into a 50 ohm load? With the bare base K2, the RF detector must see a 50 ohm non-reactive load to have good power indication.
The KAT2 or KAT100 or KPA100 have real wattmeters which fix that condition. 73, Don W3FPR On 4/9/2012 5:17 AM, oe9fwv wrote: > thank you Don, > > When I tested the K2 on all bands, I found there is still a problem left. > output power on 40 and 80m is only 5 or 6 W max. > The power display on the K2 shows up to 15 W, but on my accurate LP100 meter > there is only 6 W out. > Output on 1.8, 10-28 Mhz is normal. > I think this has come up since I corrected the problem with the L33 lead. > > Do I need any readjustment? > > TIA, Werner OE9FWV > > > > -- > View this message in context: > http://elecraft.365791.n2.nabble.com/K2-intermittent-probem-in-RX-and-TX-tp7447445p7449218.html > Sent from the Elecraft mailing list archive at Nabble.com. > ______________________________________________________________ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:[email protected] > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html