John,

What are your filter settings?

The default filter settings in DATA A are Fc = 1500 Hz, width = 500 Hz. 
The JT65 "sub-band" is 2 kHz wide, centered at 1270 Hz, so with the 
default DATA A filter setting you will only be able to copy a small 
fraction of the sub-band and therefore only a small fraction of the 
signals that are on at any time. Your K3's filter width should be set to 
2.5 kHz or so to cover the whole JT65 sub-band.

73,
Rich VE3KI

N9KW wrote:

> I recently downloaded JT656HF by W6CQZ and have on several occasions 
> monitored 14.076 \
> MHZ with my K3/Signalink USB using this software.  I am still in the process 
> of \
> trying to set up the software and gaining an understanding of how to use it.  
> I \
> experience the following:  1) If I set my K3 in data mode A, no decoding of 
> JT65 \
> signals occurs during the 12 second decoding period, but 2) if I set my K3 in 
> the USB \
> mode, decoding of the JT65 signals does occur in the 12 second decoding 
> period.  I \
> have not tried any transmissions.  I would appreciate any advice/solutions so 
> that I \
> can use data mode A with JT65HF.
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to