John, What are your filter settings?
The default filter settings in DATA A are Fc = 1500 Hz, width = 500 Hz. The JT65 "sub-band" is 2 kHz wide, centered at 1270 Hz, so with the default DATA A filter setting you will only be able to copy a small fraction of the sub-band and therefore only a small fraction of the signals that are on at any time. Your K3's filter width should be set to 2.5 kHz or so to cover the whole JT65 sub-band. 73, Rich VE3KI N9KW wrote: > I recently downloaded JT656HF by W6CQZ and have on several occasions > monitored 14.076 \ > MHZ with my K3/Signalink USB using this software. I am still in the process > of \ > trying to set up the software and gaining an understanding of how to use it. > I \ > experience the following: 1) If I set my K3 in data mode A, no decoding of > JT65 \ > signals occurs during the 12 second decoding period, but 2) if I set my K3 in > the USB \ > mode, decoding of the JT65 signals does occur in the 12 second decoding > period. I \ > have not tried any transmissions. I would appreciate any advice/solutions so > that I \ > can use data mode A with JT65HF. ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html