Charles you have a shorted cell within the battery. It is a fatal error. The battery must be replaced. Shorting of cells occurs when the battery is allowed to remain in a discharged state, particularly in freezing weather.
Fred, AE6QL -----Original Message----- From: [email protected] [mailto:[email protected]] On Behalf Of Charles Nagel Sent: Tuesday, May 08, 2012 7:37 AM To: [email protected] Subject: [Elecraft] Battery Life K2 Has anyone had any long term experience with the K2 battery? I think I used it once for about three hours a couple of field days ago. Now at 14.2 volts over a couple days' charge I can't get above 11.6 volts. Charles, K0CW Sent from my iPad ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html